Product Description
- Place the label chip position to the center position that the microscope can see;
- Toggle the label clamping switch to clamp the label;
- Turn on the label vacuum adsorption switch;
- Adjust the left, right and height position of the push knife, preferably directly behind the chip;
- It is better to move the push knife to the position near the chip by jog, and the height of the push knife and the chip height can be clearly seen;
- Press the one-key test button to perform thrust test, and then write down the maximum thrust value;
- Press the push knife reset button to reset the push knife;
Detailed Photos
1. By use of Zoom-stereo microscope from 7 to 45 in amplification range;
2. Special push-type broach design is more available in RFID using;
3. High standard push-pull tester to ensure the range to 5kgf;
4. Automatic clamping for labels and support vacuum adsorption function;
5. Position of push-type broach is available for micro-adjustment of L/R, H/L;
6. Controlled by PLC+ Touch Screen, the broach supports adjustment for rate/route of travel;
7. Good appearance and durable for using in long time.